No. 88, Reclamation Road, Colombo 11.   Tel : 242 1009 (Hunting) Fax : 244 9590 ( Office hours)   Fax : 255 1313 (After Office Hours)
Branch : 108, Keyzer Street, Colombo 11.  
E-MAIL : robertagenciesltd@gmail.com

HOME | ABOUT US | TO REACH US                                                                                             Page No   1   2   3 

Analog Meters       Clamp Meters      Digital Meters     Insulation Testers

CLAMP METERS "SANWA" MADE IN JAPAN

 

MODEL : DCM10ADL
ITEM CODE : M 313

 

 

Range

Accuracy

DCA 200A /10000A ±1.5% rdg ±5dgt
ACA 200A/1000A ±1.5% rdg ±5dgt (50/60Hz)

 

MODEL : DCL 10
ITEM CODE : M 219A

 

 

 

 

 

CLAMP METERS "KYORITSU" MADE IN JAPAN

 

 

MODEL : 2805
ITEM CODE : M 264

 

KYORITSU

 

Function

Measuring Range

Accuracy

AC

6/20/60/200/600A

3%of full scale.

50Hz /60Hz

ACV

Resistance

150/300/600V

0~2kΩ

3%of full scale.

±3%of full scale. length

Frequency

50Hz 400Hz

 

 

MODEL : 2003
ITEM CODE : M 272

 

KYORITSU

 

Function

Measuring Range

Accuracy

DC 400A/2000A ±1.5%rdg ±2dgt

AC

400A/2000A

±1.5%rdg±2dgt(50/60Hz)

±3.0%rdg±4dgt(40~1kHz)

±3.0%rdg ±2dgt(50/60Hz)

DC 400V1000V ±1.0%rdg ±2dgt

AC

400V

750V

±1.5%rdg ±2dgt(50/60Hz)

±1.5%rdg ±4dgt(40~1kHz)

Resistance 400W/4000Ω ±1.5%rdg ±2dgt

 

MODEL : 2007
ITEM CODE : M 242

 

KYORITSU

 

Func:

Measuring Range

Accuracy

AC

400A(0~399.9A)

600A(0~599A)

±1.5%rdg ± 4dgt(50/60Hz)

±2.0%rdg ±5dgt

(40~400Hz)

AC

400V(0~399.9V)

750V(0~749V)

±1.2%rdg±3dgt 50/60Hz)

±1.5%rdg ± 4dgt

(40~400Hz)

Resis-tance

400(0~399.9Ω)4kΩ (0.150~399.9kΩ)

±1.5%rdg ± 2dgt

    

 

MODEL : 2031
ITEM CODE : M 295

 

KYORITSU

 

 Range

Accuracy

20A

0~19.99A

±2.0%rdg ± 5dgt

(50Hz~1kHz)

200A

0~19.99A

±2.0%rdg ± 5dgt

(50-60Hz)

±3.0%rdg ± 10dgt

(40Hz~1kHz)

NISHIZAWA

 

MODEL : 5127
ITEM CODE : M H42

 

NISHIZAWA

 

 

 

Func:

Measuring Range

ACA

6/15/60/150/300A f.s. reading ±3%/50Hz 1kHz)

ACV

150/300/750V f.s.reading   3%

DCV

75V f.s. reading   3%

Ω

0~1k W Central scale 30W Rx1.Rx100
Scale length   3%

Tempera-ture/Scale

-50°C ~+200°C (with optional probe)

Protective

System

Protection in range up to AC250V
commercial power input.

Dimensions

Weight

 190H x 78Wx34D(mm)
 Approx. 340g

 

MODEL : 2010
ITEM CODE : M 357

 

KYORITSU

 

AC/DC clamp meter.

 

AC A

200mA/2/20A
|±1%rdg±2dgt [50/60Hz] (200mA)
|±1.5%rdg±4dgt [40Hz~2kHz] (200mA)
|±1%rdg±2dgt [50/60Hz] (2A)
|±2.5%rdg±5dgt [40Hz~2kHz] (2/20A)

DC A

2/20A |±1%rdg±2dgt (2A)
|±1.5%rdg±4dgt (20A)

Output Voltage

200mV DC for 200mA AC/DC and

2A/20A AC/DC full scale

Conductor Size

Ø7.5mm max.

Frequency Response

DC, 40Hz~2kHz

Withstand Voltage

750V AC for 1 minute

Power Source

6LF22(9V) × 1 or AC Adaptor

Dimensions

142(L) × 64(W) × 26(D)mm
153(L) × 23(W) × 18(D)mm
Clamp Sensor

Weight

220g approx.

Accessories

9071(Carrying Case) Alkaline 6LF22 × 1
Instruction Manual

Optional

8022(AC Adaptor)(110V) 8023(AC Adaptor)(220V) 7014(Output Cord)

High sensitivity, miniature AC/DC clamp meter.
0.1mA minimum resolution for AC current and 1mA minimum resolution for DC current.
Output terminal for recorder connection.

MODEL : 4200
ITEM CODE : M 360

 

KYORITSU

 

EARTH CLAMP TESTER

 

 

Function

Range

Resolution

Measuring range

Accuracy

Earth resistance Auto range

20Ω

0.01Ω*

0.00~20.99Ω

|±1.5%±0.05Ω

200Ω

0.1Ω

16.0~99.9Ω

|±2%±0.5Ω

100.0~209.9Ω

|±3%±2Ω

1200Ω

160~399Ω

|±5%±5Ω

400~599Ω

|±10%±10Ω

10Ω

600~1260Ω

---

AC current
(50Hz / 60Hz)
Auto range

100mA

0.1mA

0.0~104.9mA

|±2%±0.7mA

1000mA

1mA

80~1049mA

|±2%

10A

0.01A

0.80~10.49A

30A

0.1A

8.0~31.5A

Operating system

Earth resistance function :

Constant voltage injection,
Current detection,
(Frequency : Approx.2400Hz)
Dual Integration

AC current function :

Successive Approximation

Over-range indication

"OL" is displayed when input exceeds the upper limit of a measuring range

Response time

Approx.7 seconds (Earth resistance)
Approx.2 seconds (AC current)

Sample rate

Approx. 1 times per second

Power source

DC6V : R6P(sizeAA manganese battery) × 4pcs,
or LR6(sizeAA alkaline battery) × 4pcs

Current consumption

Approx. 50mA (max. 100mA)

Measurement time

Approx. 12 hours (when R6P is used)
Approx. 24 hours (when LR6 is used)

Auto power-off

Turns power off about 10 minutes after the last button operation.

Applicable standards

IEC 61010-1 : 2001 (CAT.IV 300V Pollution degree2)

Withstand voltage

AC5320Vrms / 5 seconds
Between the Transformer jaws fitted parts and Case enclosure
(except for jaws)

Conductor size

Approx. 32mm max.

Dimension

246(L) × 120(W) × 54(D)mm

Weight

Approx. 780g (including batteries)

Accessories

Battery R6P : 4pcs Instruction manual : 1pc 8304

(Resister for operation check : 1pc) 9128 (Hard case : 1pc)

 

 

MODEL : 2417
ITEM CODE : M 35
8

 

KYORITSU

 

LEAKAGE CLAMP METER

 

AC A
(50/60Hz)

200/2000mA/20/200/500A (True RMS)
|±1.5%rdg±6dgt (200/2000mA)
|±2%rdg±6dgt (20/200A)|±2.5%rdg±6dgt (500A)

AC A
(WIDE)

200/2000mA/20/200/500A (True RMS)
|±1%rdg±4dgt [50/60Hz],
|±3%rdg±4dgt [40Hz~1kHz] (200/2000mA)
|±1.5%rdg±4dgt [50/60Hz],
|±3.5%rdg±4dgt [40Hz~1kHz] (20/200A)
|±2%rdg±4dgt [50/60Hz],
|±4%rdg±4dgt [40Hz~1kHz] (500A)

Conductor Size

Ø40mm max.

Safety Standard

IEC61010-1 CAT.III 300V IEC61010-2-032

Effect of External
Stray Magnetic Field
Ø15mm 100A

10mA AC max.

Frequency Response

40~400Hz

Withstand Voltage

3700V AC for 1 minute

Power Source

6F22(9V) × 1

Dimensions

209(L) × 96(W) × 45(D)mm

Weight

450g approx.

Accessories

9079(Carrying Case) 6F22 × 1 Instruction Manual

Optional

8004/8008(Multi-Tran)*

MODEL : 2300R
ITEM CODE : M 359

 

KYORITSU

 

Range

Measuring Range

Accuracy

Current Measurement

AC A 0 to 100.0A
DC A 0 to ±100.0A

|±2.0%rdg±5dgt (50/60Hz)
|±2.0%rdg±5dgt

Conductor Size

Max Ø10mm

Non Contact Voltage

Detect AC voltage
without contacting
with socket wire

During voltage detection,
"Hi" flashes and
a buzzer sounds intermittently

Dimensions

161.3(L) × 40.2(W) × 30.3(D)mm

Crest Factor

2.5

Weight

110g (with batteries)

Maximum Digit

1,049

Safety Standard

IEC 61010-1 CAT.III 300V Pollution Degree 2

Power Source

R03 (AAA) × 2

Accessories

Carrying Case  R03 (AAA) × 2  Instruction Manual

HOME | ABOUT US | TO REACH US                                                                            Page No   1   2   3   ~Top of Page

Analog Meters       Clamp Meters      Digital Meters     Insulation Testers

No. 88, Reclamation Road, Colombo 11.   Tel : 242 1009 (Hunting) Fax : 244 9590 ( Office hours)   Fax : 255 1313 (After Office Hours)
Branch : 108, Keyzer Street, Colombo 11.  
E-MAIL : robertagenciesltd@gmail.com

 robert agencies